Heating Degree Days and Heat-Pump Bills

Published November 28, 2026, by WattAndMile. This guide uses the same official data and methods described on the About page. It is an estimate for information only, not professional, financial, or utility-billing advice. See the disclaimer.

Heating degree days are a temperature index, not a bill. They are a standard way to measure how cold a period was relative to a 65 °F base. For a heat-pump house, a cold snap can raise the bill through two different mechanisms: more hours of heating, and, below some outdoor temperature, greater use of electric resistance backup heat, which uses more electricity per unit of heat than the compressor.

The bill-jump calculator uses NOAA state degree-day totals and a stated kWh-per-degree-day coefficient to split a change in daily use into weather and other usage. This page defines the index, shows how a cold snap appears in it, and states the assumptions and limits of that weather split for heat-pump heating.

What a degree day measures

The U.S. Energy Information Administration defines a degree day from the day’s mean outdoor temperature: the high plus the low, divided by two, compared with a base of 65 °F (EIA: Degree-days).

  • If the mean is above 65 °F, cooling degree days (CDD) = mean − 65. Example from EIA: a 90 °F high and a 66 °F low give a mean of 78 °F, or 13 CDD.
  • If the mean is below 65 °F, heating degree days (HDD) = 65 − mean. EIA’s other example: a 33 °F high and a 25 °F low give a mean of 29 °F, or 36 HDD.
  • If the mean is exactly 65 °F, both are zero for that day.

Daily values are added over a billing period, a month, or a season. A month with 600 HDD was colder, in this index, than a month with 400 HDD. The index does not say how much energy a particular house used. That depends on the building, the equipment, and — for a heat pump — how much backup heat ran.

The 65 °F base is a convention used in U.S. energy statistics, so periods and places can be compared on one scale. It is not the temperature at which your system turns on.

State totals, not your town

The totals on this site come from the NOAA Climate Prediction Center’s monthly, population-weighted state heating and cooling degree days, base 65 °F (CPC degree-day products). Population weighting means a state’s figure is closer to where people live than a simple average of weather stations. It is still a state figure. A mountain county, a coastal city, and a valley town in the same state can differ from that average, and from each other, in the same month.

The bill-jump tool assigns each billing day its month’s state total divided by the number of days in that month. Days in a month that has not yet been published use the CPC normal for that month, and the result says so. That allocation spreads a monthly total evenly, so a five-day cold snap and a uniformly chilly month with the same total look the same in the index.

From degree days to kilowatt-hours

A simple model is: change in daily heating (or cooling) use ≈ coefficient × change in degree days per day. The coefficient is in kWh per degree day. The bill-jump tool’s defaults are stated as kWh per degree day per 1,000 square feet of conditioned floor area, then scaled by the floor area you enter.

The heating defaults assume a heat loss of about 5 Btu per square foot per HDD for an existing house, converted at 3,412 Btu per kWh. That is about 1.5 kWh per HDD per 1,000 square feet for electric resistance heat. A seasonal heat-pump coefficient of performance (COP) of about 2.2 reduces that to about 0.7 kWh per HDD per 1,000 square feet. Gas, oil, and propane heat are assigned only blower or circulator electricity (0.05). Cooling defaults are about 0.6 kWh per CDD per 1,000 square feet for central air conditioning (SEER 13–14) and 0.35 for room units.

These are engineering starting points, not measurements. The tool lets you change them. A house can differ by a factor of two or more. The 2.2 seasonal COP is an assumption used to set the default, not a rating for a particular unit.

A cold snap on that model

Take the heat-pump default and a 2,000 square foot house. The implied coefficient is 1.4 kWh per HDD (0.7 × 2). A later billing period that is 200 HDD colder than the earlier one would then be assigned 280 kWh of additional heating use, before any price or billing-day effects. At 16.50 ¢/kWh — the EIA average residential price for South Carolina in the site’s current table, used here only as an illustration — that 280 kWh is about $46.

That $46 is not a prediction for a real house. It is what the default coefficient says if the NOAA state totals differ by 200 HDD and the other assumptions hold. Price and billing-day effects are reported separately. If backup resistance heat ran hard, the true kWh per HDD can be higher than 0.7 per 1,000 square feet, and some of the increase will appear as “other usage” unless you raise the heating coefficient.

Why backup heat changes the coefficient

An air-source heat pump moves heat; it does not generate all of the delivered heat in electric-resistance coils. When the compressor is providing the heat, the site energy per unit of delivered heat is lower than for resistance heat (COP greater than 1). As the outdoor temperature falls, two things typically happen: the building’s heat loss rises, and the heat pump’s capacity and efficiency fall. Below a balance point, the compressor cannot meet the load alone. Many systems then use electric resistance “strip” or auxiliary heat, which has a COP of 1, or a fossil-fuel backup.

A 2023 U.S. Department of Energy national laboratory field study of centrally ducted, variable-capacity air-source heat pumps in cold-climate homes (NREL/TP-5500-84745, Winkler and Ramaraj) reported an average seasonal compressor-based heating COP of 2.5 across twelve sites (range 1.7 to 3.5). Auxiliary electric heat lowered the overall system COP, in some cases by more than 30 percent. At 5 of 11 all-electric sites, auxiliary heat energy exceeded 40 percent of compressor-based heating energy; at 2 of those sites it exceeded the compressor. The highest auxiliary use was attributed to undersizing and controls (including strip heat after defrost and during setback recovery) and, at one site, a control or sensor fault. The report is at docs.nlr.gov (NREL/TP-5500-84745); related data are in DOE’s Heat Pump Database. It is a small field sample, not a typical-use number for every heat pump. It shows that backup heat, not just the degree-day total, can dominate a winter bill, and that a single seasonal coefficient cannot see a week when the strips ran continuously.

The U.S. Department of Energy’s Energy Saver guide (2022) is a general household reference on heating equipment, including heat pumps. It does not replace a measured coefficient from your own bills.

Calculator

Why did my electric bill jump? Enter two dated bills and a state to use NOAA CPC degree days. Open “Assumptions” to change the kWh-per-degree-day coefficients, including the heat-pump heating default of 0.7 kWh per HDD per 1,000 square feet.

Assumptions and limits

  • The official HDD/CDD index uses a 65 °F base and a daily mean from the high and the low. It is not your thermostat setpoint.
  • CPC state totals are population-weighted state figures, allocated evenly across each month. They are not a station history for your town, and they do not resolve a short cold snap inside the month any differently than a uniformly colder month with the same total.
  • The default kWh-per-degree-day values are stated assumptions. Change them if your bill history suggests otherwise.
  • Backup resistance heat, defrost, and thermostat setbacks can raise electricity use in ways the seasonal coefficient does not capture.
  • The weather term is only a split of the change in daily use. Price and billing-day effects are separate, as described in Why Your Electric Bill Jumped: Four Drivers.

Sources

  • U.S. Energy Information Administration, Degree-days.
  • NOAA / NWS / NCEP Climate Prediction Center, degree-day products. The site currently loads August 2024 to October 2026.
  • Winkler, J., and S. Ramaraj, Field Validation of Air-Source Heat Pumps for Cold Climates, NREL/TP-5500-84745, 2023, U.S. Department of Energy national laboratory report.
  • U.S. Department of Energy, Heat Pump Database.
  • U.S. Department of Energy, Energy Saver: Tips on Saving Money and Energy in Your Home, 2022.
  • U.S. Energy Information Administration, Electric Power Monthly Table 5.6.A, used above only to illustrate a state average price. Current vintage: September 2026.

Related: Why Your Electric Bill Jumped: Four Drivers · Bill-jump calculator · All guides · About and methodology

  • About and methodology
  • Guides
  • Disclaimer
  • Attribution
  • Privacy
  • Affiliate disclosure

These figures are estimates for information only, not professional advice. State averages are not your utility’s rates. Data may lag official releases. This site is not affiliated with or endorsed by EIA, DOE, EPA, or FuelEconomy.gov.

Attribution. Electricity and gasoline prices: U.S. Energy Information Administration. This site is not endorsed or certified by EIA. Vehicle fuel-economy figures: Courtesy of FuelEconomy.gov, U.S. Dept. of Energy. This site is not endorsed or certified by DOE, EPA, or FuelEconomy.gov. Vehicle photographs are not used and may not be copied from FuelEconomy.gov.

Sources: EIA Table 5.6.A · EIA Gasoline and Diesel Fuel Update · FuelEconomy.gov web services · official vehicle CSV.